200–240 V batteriurladdningstestare, belastningsbank, hög prestanda

SKICKA ETT MEDDELANDE TILL OSS

    Produktparametrar

    Place Of Origin China
    Name: Testare för batteriets urladdning AC Power Input Range: 200~240V
    Discharge Input Voltage Range: 5~ 100V Discharge Current Range: 0~20A
    Maximum Discharge Power: 2000W Voltage Display Accuracy: 0.01V
    Highlight: 240V Battery Discharge Tester, 240V load bank for battery discharge test,
    high performance Battery Discharge Tester

     

    Introduction

    Charge discharge test equipment is mainly used for lithium battery charge discharge cycle test.

     

    Test Items

    Battery charging protection voltage, discharge protection voltage, capacity, etc. The device has four test steps: charging, discharging, shelving and cycling. By editing the corresponding steps, the battery can be tested according to the set process.

     

    EL2000 Functions

    EL2000 electronic load is suitable for aging and discharging batteries of various voltages. It can set the discharge current, set and record the discharge cut-off voltage, discharge capacity, discharge time and other parameters, and check whether the battery pack is qualified according to the test data.

     

    Technical Parameter

    parameter figure units descr
    AC power input range 200~240 V AC power
    Discharge input voltage range 5~ 100 V DC
    Discharge current range 0~20. A
    Maximum discharge power 2000 W
    Voltage display accuracy 0.01 V
    Current display accuracy 0.01 A
    Capacity display accuracy 0.01 Ah
    Time display accuracy 0.1 M min
    Fan starting condition Bringing onto load
    size 46*40*20CM
    weight 20KG

     

    On the left: the “Set/Shift” key; on the right: the “Start/Confirm” key; above: the “Increase” key; below:

    “Decrease” key.