YM-HR Pure Sine Wave Off Grid Inverter Three-In-One ISO9001 Approval

ENVÍANOS UN MENSAJE

    Parámetros del producto

    Place Of Origin China
    Certification ISO14001 ISO9001 Model Number YM-HR
    Product Name Inversor autónomo Rated Capacity 1Kw-12Kw
    Series Pure Sine Wave Series Warranty 5 Years
    OEM/ODM Available Application Renewable Energy Systems, Solar Photovoltaic Systems
    Minimum Order Quantity 2 Pieces Precio Negotiable
    Payment Terms L/C, T/T Supply Ability 100000 Pieces Per Month
    Highlight ISO9001 Off Grid Inverter, Off Grid Inverter Three-In-One, Three-In-One solar Grid inverter

     

    Product features:

    1. Contains four functions of mains bypass, mains charging, inverter, UPS, fully automatic switching

    2. The efficiency is 3~5% higher than the ordinary power frequency series, and the self-consumption is reduced by 30~50%

    3. Three-in-one function, inverter & control & lithium battery integrated cabinet

    4. DIP switch selection: battery undervoltage point, input AC range, energy saving mode, priority mode

    5. Remote Communication Interface RJ11 / RJ45 / RS232 / 485 App Monitoring Remote Control Panel (optional)

    6. Pure sine wave output, input and output is completely isolated

    7. Contains the four-stage charging mode, the charging current is automatically adjusted

    8. Mixed power supply such as the power generation of the main electricity, built-in solar MPPT controller

    9. Tolerate 3 times rated power start, carry capacity excellence

    10.LED Display working conditions, LCD remote display running parameters

    11. undervoltage / overvoltage / short circuit / overload / over temperature protection

    12. Pure sine wave series inverter is suitable for renewable energy systems, utilities, Route,oceanand emergency application.

     

    20240328144938_1594720240328144948_94081

     

    HR series parameter table

    NO MODEL ESS-HR3048 ESS-HR5048 ESS-HR6048 ESS-HR8048 ESS-HR10048 ESS-HR12048
    1 battery voltage 51 .2Vdc
    2 battery capacity 2OOAH 2OOAH 3OOAH 4OOAH 5OOAH 6OOAH
    3 battery power 1 0.24 KWH 1 O.24KWH 1 5.36 KWH 2O.48KWH 25.6KWH 3O.72KWH
    4 Battery configuration 48V200AH

    *1PCS

    48V200AH*1PCS 48V15OAH

    *2PCS

    48V200AH*2PCS 48V175AH*3

    PCS

    48V200AH*3

    PCS

    5 Numberof batteries 48V20OAH

    1PCS

    48V200AH

    1PCS

    48V15OAH

    2PCS

    48V200AH

    2PCS

    48V175AH

    3PCS

    48V200AH

    3PCS

    6 Rated charging voltage 56.Ovdc
    7 Maximum

    charging voltage

    58.4vdc
    8 Overcharge protection 58.4vdc
    9 Rated charging current 5OA 5OA 60A 8OA 10OA 12OA
    1O Maximum charging current 8OA 80A 10OA 12OA 15OA 20OA
    11 Overcharge protection Reboot
    12 Charging temperature 0~45℃
    13 Output

    voltage range

    4O-56Vdc < 46Vdc or 48Vdc inverter cut off by SW1 setting >
    14 Nozzle discharge current 12OA 12OA 24OA 240A 36OA 36OA
    15 Maximum discharge current 24OA 24OA 30OA 40OA 50OA 60OA
    16 Overcharge protection Reboot
    17 Discharge temperature 0~45℃
    18 Communication Interface RS485 for LCD/CAN Computer monitoring
    Inverter <built-in) HR3O48 HR5O48 HR6O48 HR8O48 HR10O48 HR12048
    1 rated power 3KW 5KW 6KW 8KW 10KW 12KW
    2 Output voltage waveform Pure sine wave (mains or generator)
    3 Rated efficiency >88% (peak) inverter mode />95% line mode
    4 Power factor 0.9-1.0
    5 Rated output voltage 220Vac or 230Vdc or 240Vac or 110Vac or 120Vac (L-N)

    &240Vac ( H-H)120Vac ( H-N)±10%RMS

    6 Output frequency 50 or 60±0.3HZ (inverter mode set by sw4))
    7 Typical switching time 4-6 seconds typical, 10 seconds (maximum)
    8 Total harmonic distortion <3%<rated voltage)
    9 AC input range 184-253Vac (UPS mode) or 140-270Vac (Generator mode)

    /96-135 (UPS mode) or 80-135Vac (Generator mode)

    1O Custom AC charger Battery type selector posial9, LEP special design,

    maximize battery cycle life

    11 Maximum AC current 60A 60A 8OA 1OOA 12OA 12OA
    12 Battery priority function Set by SW5 at position 1 <inverter mode valid)-,

    AC automatic input battery voltage is lower than 48Vdc or 50Vdc

    13 No charge for

    AC bypass

    Battery type selector position 0
    MPPT (built-in) 60A 100A 6OA*2 8OA*2 100A*2 80*3
    1 PV 3400W 5600W 34OOW*2 454Ow*2 56OOW*3 4540w*3
    2 Photovoltaic Discovery Group 1 1 2 2 3 3
    3 PV input range 65-15OVdc
    4 MPPT charging voltage 56.4V (fast charge) / 54V (fast charge)
    Mechanical parameters ESS-HR3048 ESS-HR8048 ESS-HR6048 ESS-HR8048 ESS-HR10048 ESS-HR12048
    1 size(H*W*D>) 800*600*

    600mm

    1000*600*

    600mm

    1000*600*

    600mm

    1200*600*

    600mm

    1200*600*

    600mm

    1300*600*

    600mm

    If the product model specification changes without notice