High Performance YM-HC Off Grid Power Inverter 1000W To 6000W

ENVOYEZ-NOUS UN MESSAGE

    Paramètres du produit

    Référence YM-HC Product Name: Onduleur hors réseau
    Rated Capacity: 1Kw-12Kw Series: Pure Sine Wave Series
    Warranty: 5 Years OEM/ODM: Available
    Application: Renewable Energy Systems,
    Solar Photovoltaic Systems
    Minimum Order Quantity: 2 pièces
    Price: Negotiable Payment Terms: L/C, T/T
    Supply Ability: 100 000 pièces par mois
    Highlight: Off Grid Power Inverter 1000W, Off Grid Power Inverter 6000W, pure sine wave inverter 1000W
    PRODUCT DESCRIPTION:
    HC series pure sine wave inverter, a multifunctional inverter integrating charger and automatic AC transferswitch, the highest conversion rate is 88%.Features: power factor correction, multi-stage charging only and pure sine wave output, and withunprecedented peak power to meetThe power demand of the inductive load does not endanger the equipment itself. For conventional machines, when the mains AC power is cut off (the fire exceeds theacceptable range),When the transfer relay is disconnected, the loadcan be automatically transferred to the output of the inverter. Once the AC powerreturns, the relay is connected. The load can be automatically re-driven by the mains AC
    PRODUCT FEATURES:
    1. Contains four functions of mains bypass, mains charging, inverter,UPS, fully automatic switching
    2. The efficiency is 3~5% higher than the ordinary power frequency series, and the self-consumption
    is reduced by 30~50%
    3. DIP switch selection: battery undervoltage point, input AC range, energysaving mode, priority mode
    4. Remote communication interface RJ11/RJ45/RS232/485 remote control panel (optional)
    5. Support PC software monitoring, support WIFI 4G module expansion to realize app cloud monitoring (optional)
    6. Pure sine wave output, input and output completely isolated design
    7. Contains AC four-stage charging mode, and the charging current is automatically adjusted
    8. It can be matched with commercial power, diesel engine power generationand other mixed power supply
    9. Can withstand 3 times the rated power start, excellent load capacity
    10. LED display working status, LCD remote display operating parameters
    11. Undervoltage/overvoltage/short circuit/overload/over temperature protection
    12. Pure sine wave series inverters are suitable for renewable energy systems, utilities, RVs,Marine and emergency applications.
    20240328144203_8943420240328144212_53382
    Parameter
    MODEL(HC) 1kw 1.5kw 2kw 3kw 4kw 5KW 6KW
    Continuous Output Power (W) 1000W 1500W 2000W 3000W 4000W 5000W 6000W
    Rated input voltage 12VDC/24VDC/48VDC 12VDC/24VDC/48VDC 24VDC/48VDC
    Mains mode specifications:
    Input voltage waveform Sine wave (mains or generator)
    Rated input voltage 100V/ 110V/ 120V/220V/230V/240Vac
    Low voltage

    shutdown point

    92/ 184Vac±4%
    Low pressure recovery point 97/ 194Vac ±4%
    High voltage

    shutdown point

    127/253Vac±4%
    High pressure recovery point 121/243Vac±4%
    Maximum

    AC input voltage

    135/270V rms
    Rated input frequency 50Hz/ 60Hz (automatic detection)
    Low voltage recovery point frequency 40.5+0.3Hz ;
    Low voltage cut-off point frequency 40+0.3Hz;
    High voltage recovery point frequency 69.5+0.3Hz;
    High voltage cut-off point frequency 70+0.3Hz ;
    Output voltage waveform Consistent with the input voltage waveform
    Overload protection Circuit breaker start
    Short circuit protection Circuit breaker start
    Power Efficiency >95%
    Conversion current 30A
    Conversion time (Ac to Dc) 10ms
    Bypass switching current Yes
    Bypass maximum load current 30A
    Output voltage waveform Sine wave
    Power factor 0~1.0
    Rated output voltage (V) 120/230Vac
    Rated output frequency (Hz) 60/50Hz ± 0.3Hz
    Automatic tracking main frequency (Hz) Yes (from the first connection)
    Output voltage range ±2% rms
    efficient >80%
    Overload protection (SMPS load) (110%<load<125%) ±10%: disconnect the output voltage after 15 minutes

    (125%<load <150%) ±10%: disconnect the output voltage after 10 seconds

    Load >150% ±10%: Disconnect the output voltage after 20 seconds

    Peak capacity( 10s) 3000VA 4500VA 6000VA 9000VA 1200VA 15000VA 18000VA
    start the motor 1HP 1.5HP 2HP 3HP 4HP 5HP 6HP
    Short circuit protection Current limit (power off after 10s)
    Circuit breaker size 15A 20A 30A 40A
    Rated DC input voltage 12V / 24V/48V
    Minimum DC

    terminal voltage

    10V/20V/40V
    Undervoltage warning 10.5Vdc ± 0.3Vdc (12V power supply)
    DC input voltage is too low, automatic power off 10.0Vdc ± 0.3Vdc(12V power supply)
    Input overvoltagewarning and power failure 16Vdc ± 0.3Vdc (12Vpower supply)
    Input overvoltage recovery 15.5Vdc ± 0.3Vdc(12V power supply)
    Power saving load ≦2W
    Inverter dimensions 360*185* 180mm 420*185* 180mm 597* 195* 190mm
    (Length*width*height)
    Packing size

    (length*width*height)

    520*315*305 580*315*305mm 760*325*310mm
    Inverter weight 13.5KG 14KG 17KG 21KG 27KG 29.5KG 30.5KG
    Packing operating weight 15.5KG 15.5KG 19KG 23.5KG 29.5KG 31.5KG 32.5KG
    Standard warranty 2 year

     

    If the product model specification changes without notice